HOME > Saivs brand > hydraulic pump

  • 1-220524102015L8
1-220524102015L8

PVQ-1X series Rexroth Vane Pump

5out of5 based on2 reviews | Write a review
  • Model:PVQ-1X    

    Name: hydraulic pump

    Pump Type: Vane Pump  

    SIZE: 018~193  

    Place of Origin:Zhejiang, China  

    Power:Hydraulic Packaging & Delivery

    Material:aluminium           

    Warranty:1 Year  &

    Minimum Order:9 Pieces

    Supply Ability:1800 Piece/ Month

Model:PVQ-1X    

Name: hydraulic pump

Pump Type: Vane Pump  

SIZE: 018~193  

Place of Origin:Zhejiang, China  

Power:Hydraulic Packaging & Delivery

Material:aluminium           

Warranty:1 Year    

Minimum Order:1 Pieces

Supply Ability:1500 Piece/ Month

Frame size


1245

Size


18272727464045556068698298113122139154162183193

Component series


1X

Mounting type


Flange mounting according to SAE J744

Line connections


SAE flange design (mounting thread: UNC)

Installation position


Any, inlet port at top preferred

Shaft load


Radial and axial forces cannot be transmitted

Direction of rotation


Drive direction of rotation clockwise or counterclockwise

Drive


Direct, coaxial drive

Drive speed 1) 2)

n

 

rpm

600 ... 2,700600 ... 2,500600 ... 2,400600 ... 2,200

Displacement

Vg

 

cm³

1827.436.439.545.940.145.455.26067.56981.697.7112.7121.6138.6153.5162.2183.4193.4

Drive power 3)

Pmax

 

kW

1.11.52.2345.57.511

Flow, max. 4)

qV

 

l/min

263953597059668089100101120141167177203223234267285

Operating pressure, absolute

Inlet 5)

pmin-max

 

bar

0.83 ... 2.4 6)0.83 ... 2.40.83 ... 2.4 6)

Outlet

pmax

 

bar

210160140210175

Pressure peak

pmax


At most 10 % over the max. permanent output pressure; not longer than 0.5 s

Mass 7)

m

 

kg

1214.82334
1)At 1 bar inlet pressure
2)If phosphoric acid esters (HFD-R) are used, adm. nmax = 1200 rpm
3)At Δp ≈ 0 bar, n ≈ 1450 rpm
4)at n = 1500 rpm, p = 0,7 bar, v = 25 mm2/s
5)Recommended: 1 ... 1,35 bar
6)If liquids containing water and phosphoric acid esters are used, at least 0,9 bar
7)Single pump without through-drive

Hydraulic fluid

Permissible hydraulic fluid 1)


Mineral oil (HLP) to DIN 51524-2

Hydraulic fluid temperature range 2)

°C

-10 … +70

Viscosity range

mm²/s

13 … 860

Maximum admissible degree of contamination of the hydraulic fluid 3)


Class 20/18/15 according to ISO 4406 (c)
1)For more information and data on the use of other hydraulic fluids please contact us.
2)Observe the admissible viscosity range!
3)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

For applications outside these parameters, please consult us!

The specified values for the max. drive speed apply to an absolute pressure at the input of 1 bar.

Depending on the absolute pressure at the input, the admissible max. speed must be corrected according to the following diagram.

PVQ-1X1.jpg

PVQ-1X2.jpg


PROVIDING EXCELLENT SOLUTIONS BY SAIVS™


Speak to one of our experts today to learn more about our products solutions.


Request a Quote

  • Q. Are you a factory or trading company?
  • A. Our company is an integrated set of industry and trade company.
  • Q. How to ensure the quality of your products?
  • A. IS09000, client requirements, product standards, strict inspection to control raw material, production process and final products.
  • Q. What is the MOQ?
  • A. It depends, different products will be different Sample order is acceptable, and some samples can be free.
  • Q. How long do you need the delivery time?
  • 1)Supply within 5 -10 days (If products are in our stock list). 2)Customized products need to be calculated according to the quantity.
  • Q.What 's your payment terms?
  • A. T/T, L/C
  • Q.How can we get your price ?
  • A. We need below information to quote for you: 1. Product Name 2.technical parameter 3. Dimension 4. identity
  • Write your review for PVQ-1X series Rexroth Vane Pump
    • Bad
    • Excellent